Horstmann Product Booklet

Page 1

@

Product Catalogue


Horstmann, advanced simplicity

Control, it's what we're good at and in domestic central heating and hot water installations that means more accurate control of time and temperature all around the system.

Sometimes the solution needs to be simple, like a room stat and timer installation or it can be more sophisticated requiring 3 or 4 channel electronic programmers which can independently handle hot water and separate heating zones.

Our latest electronic room thermostats are clever too. Their latest thermostat technology is proven to save up to 10% in energy costs* by increasing the efficiency of the boiler firing regime.

Wireless, mains or battery versions of our controls are available across the Horstmann range. Well worth checking out.

Horstmann... Together, we're in control.


Contents Page Programmable Room Thermostats

1- 10

C-Stat 11-ZW / C-Stat 17-ZW

1

C-Stat 11-B / C-Stat 17-B

3

C-Stat 11-M / C-Stat 17-M

5

ThermoPlus AS2-RF

7

ThermoPlus AS1 / AS2 / PRT1

9

Time Controls

11 - 24

ChannelPlus

11

ChannelPlus H37XL

13

ChannelPlus H47XL

15

CentaurPlus

17

CentaurPlus ZW

19

ServicePlus

21

425

23

Thermostats

25 - 30

HRT4-ZW / HRT4-B

25

HRT4-A / HTT4 / HFT4

27

HCT2

29

Motorised Zone Valves

31-32

ZonePlus Z Series

31

Electric Water Heating

33 - 42

Electrisaver

33

Electronic 7

35

Economy 7 Quartz

37

BX2000

39

E7BX

41


Additional Information

43 - 55

Electric Water Heating Controls – Schematic diagrams

43

Internal wiring diagrams

44 - 46

TPI

47

Optimum Start

48

Programmer replacement and wiring guide

49 - 54

Thermostat compatibility guide

55

Programmable thermostat compatibility guide

56


C-Stat 11-ZW and 17-ZW Wireless Z Wave programmable room thermostat with mains powered receiver

Programmable room thermostats are widely recognised as one of the best ways in which to control central heating. Our C-Stat programmable room thermostats have a large display and intuitive user interface, making them easy to set up and use. C-Stat uses a sophisticated time proportional integral (TPI) algorithm for accurate temperature control and energy efficiency. The latest Z Wave wireless technology is employed for superior reliability C-Stat is the ideal control for combi boilers, extra heating zones or for retro fitting into an existing system with no room stat. Features ! ! ! ! !

! !

! ! ! ! !

Battery powered wireless room thermostat Mains powered receiver – voltage free contacts Choice of 24 hour or 7 day versions Up to six target temperature settings per day Menu driven programming via large back-lit display, with prompts to aid the user Automatic daylight saving time adjustment Target temperature and actual room temperature indication Temporary temperature override Holiday programme Tamperproof security code Optional optimum start facility Temperature settings - 5°c to 30°c

1


Specification C-Stat 11-ZW and 17-ZW Ÿ Ÿ Ÿ Ÿ Ÿ

Reduced energy costs No additional wiring when installing the Z Wave wireless version in existing installations No disruption to decor Reliable Z Wave wireless connection Battery and Mains versions are also available in this range

Thermostat POWER SUPPLY CONTACT TYPE WIRING CONFIGURATION CONTACT VOLTAGE RATING TEMPERATURE DIFFERENTIAL TEMPERATURE ACCURACY DESIGN STANDARDS DIMENSIONS ENCLOSURE ENCLOSURE PROTECTION POLLUTION DEGREE INSULATION CLASS OPERATING TEMPERATURE RANGE CLOCK

SETTINGS PER DAY TRANSMITTER FREQUENCY RECIEVER CATEGORY POWER CLASS

2 x AA Batteries Micro-disconnection Voltage free c/o contacts (SPDT) 230V AC 50Hz (30V dc) 0.5°c +/- 0.5°c at 21°c BS EN 60730-2-9 100 x 120 x 26.5mm Flame retardant thermoplastic IP30 Degree 2 Double insulated 0° C to 40 °c 12 / 24 Hour with Automatic BST / GMT adjustment 6 target temperature settings per day 868 MHz Category 3 Class B

Receiver POWER SUPPLY CONTACT TYPE VOLTAGE RATING OPERATING TEMPERATURE RANGE INSULATION CLASS RATED IMPULSE VOLTAGE POLUTION DEGREE ENCLOSURE PROTECTION DIMENSIONS MOUNTING

230V AC 50Hz Micro-disconnection, Voltage Free Contact 3 (1) Amps 230V AC 0 °C to 40 °c Double insulated Cat 2 – 2500V Degree 2 Flame retardant thermoplastic 86 x 86 x 36.25mm 6 terminal plug in wall plate

2


C-Stat 11-B and 17-B Battery powered programmable room thermostat Programmable room thermostats are widely recognised as one of the best ways in which to control central heating. Our C-Stat programmable room thermostats have a large display and intuitive user interface, making them easy to set up and use. C-Stat uses a sophisticated time proportional integral (TPI) algorithm for accurate temperature control and energy efficiency. Being battery powered, these models are suitable for replacing most existing room thermostats. C-Stat is ideal for combi boilers, extra heating zones or upgrading older inefficient room thermostats. Features ! ! ! ! !

! !

! ! ! ! !

Voltage free contacts Choice of 24 hour or 7 day versions Up to six target temperature settings per day Temperature Settings - 5째c to 30째c Menu driven programming via large back-lit display, with prompts to aid the user Automatic daylight saving time adjustment Target temperature and actual room temperature indication Temporary temperature override Holiday programme Optional high and low temperature limits Tamperproof security code Optional optimum start facility

3


Specification C-Stat 11-B and 17-B Ÿ Ÿ

Ÿ Ÿ Ÿ

Reduced energy costs Minimal boiler cycling and reduced flow temperatures through use of sophisticated TPI control algorithms Runs on 2 standard AA type batteries No need for additional wiring when replacing an existing thermostat Frost protection setting

Wireless and Mains versions are also available in this range

POWER SUPPLY CONTACT TYPE WIRING CONFIGURATION CONTACT VOLTAGE RATING CONTACT CURRENT RATING TEMPERATURE DIFFERENTIAL TEMPERATURE ACCURACY DESIGN STANDARDS DIMENSIONS ENCLOSURE ENCLOSURE PROTECTION POLLUTION DEGREE INSULATION CLASS OPERATING TEMPERATURE RANGE CLOCK

SETTINGS PER DAY MOUNTING

2 x AA Batteries Micro-disconnection Voltage free c/o contacts (SPDT) 230V AC 50Hz (30V dc) 8A (1A inductive) 0.5°c +/- 0.5°c at 21°c BS EN 60730-2-9 100 x 120 x 26.5mm Flame retardant thermoplastic IP30 Degree 2 Double insulated 0 °C to 40 °C 12 / 24 Hour with Automatic BST / GMT adjustment 6 target temperature settings per day 6 terminal plug in wall plate

4


C-Stat 11-M and 17-M Mains powered programmable room thermostat Programmable room thermostats are widely recognised as one of the best ways in which to control central heating. Our C-Stat programmable room thermostats have a large display and intuitive user interface, making them easy to set up and use. C-Stat uses a sophisticated time proportional integral (TPI) algorithm for accurate temperature control and energy efficiency. Being mains powered these models won't need the batteries changing every two years. C-Stat –M is ideal for control of combi boilers or extra heating zones where no thermostat has been fitted previously. Features ! ! ! !

! !

! ! ! ! !

Voltage free contacts Choice of 24 hour or 7 day versions Up to six target temperature settings per day Menu driven programming via large back-lit display, with prompts to aid the user Automatic daylight saving time adjustment Target temperature and actual room temperature indication Temporary temperature override Holiday programme Tamperproof security code Optional optimum start facility Battery Reserve

5


Specification C-Stat 11-M and 17-M Reduced energy costs Ÿ Minimal boiler cycling and reduced flow temperatures through use of sophisticated TPI control algorithms Ÿ Frost protection setting Ÿ No battery replacement required Ÿ

Wireless and Battery versions are also available in this range

POWER SUPPLY CONTACT TYPE WIRING CONFIGURATION CONTACT VOLTAGE RATING CONTACT CURRENT RATING TEMPERATURE DIFFERENTIAL TEMPERATURE ACCURACY IMPULSE RATING DESIGN STANDARDS DIMENSIONS ENCLOSURE ENCLOSURE PROTECTION POLLUTION DEGREE INSULATION CLASS OPERATING TEMPERATURE RANGE CLOCK

SETTINGS PER DAY MOUNTING

230V 50Hz Micro-disconnection Voltage free c/o contacts (SPDT) 230V AC 50Hz (30V dc) 8A (1A inductive) 0.5°c +/- 0.5°c at 21°c Category II 2500V BS EN 60730-2-9 100 x 120 x 26.5mm Flame retardant thermoplastic IP30 Degree 2 Double insulated 0 °C to 40 °C 12 / 24 Hour with Automatic BST / GMT adjustment 6 target temperature settings per day 6 terminal plug in wall plate

6


ThermoPlus AS2-RF Wireless Programmable Room Thermostat The ThermoPlus AS2-RF is an intelligent wireless programmable thermostat, which transmits control signals to an RF receiver unit via Z-wave mesh radio technology. The ThermoPlus range was designed following research showing the difficulties visually or dextrally impaired people have whilst using heating controls, it is easy to install and easy to use. Perfect where installing additional wiring is difficult and where a straightforward easy to use programmable thermostat is required. Ÿ Wireless radio frequency connection Ÿ Colour coded, bright LED Warm/ Cool display and Braille Ÿ Ÿ Ÿ Ÿ

markings on the main override buttons Preset clock with battery back-up Automatic BST / GMT time change Audible and tactile feedback Back lit LCD display

7


Specification ASR-RF is a mains powered receiver for connecting where a mains supply is readily available. AS2-RF thermostat transmits via Z wave mesh radio technology and is capable of operation in most domestic houses with an operating range of approximately 30 metres. Ideal for controlling combi boilers, it can be mounted in any suitable location without the need to disturb existing wiring or décor. Operates from 3 standard AA batteries, with 2 years+ life and separate clock battery. For day-to-day use only, 3 buttons are needed. The centre 'Warm/Cool' button changes the temperature state and the '+' and '-' buttons provide fine user adjustment as well as audible feedback. Each adjustment is immediately reflected in changes to the bright red and blue LED display. The built-in clock is programmed to the correct time during manufacture and a built-in calendar will automatically adjust for summer and winter time changes, so there's never any need for user adjustment.

CONTACT RATING AC CONTACT TYPE SUPPLY BATTERY TYPE POLLUTION DEGREE DOUBLE INSULATED ENCLOSURE PROTECTION OPERATING TEMPERATURE RANGE TEMPERATURE CONTROL RANGE STANDBY TEMPERATURE CASE MATERIAL DIMENSIONS DISPLAY CLOCK DISPLAYED TIME ADJUSTMENTS SWITCHED TIME ADJUSTMENTS OPERATING PERIODS PER DAY PROGRAMME SETTINGS OVERRIDE MOUNTING OPERATING FREQUENCY

3 (1) Amps 230-240V Micro disconnection Voltage Free 230V AC 50Hz Lithium + 3AA (AS2RF) Degree 2 Yes IP30 0 °C to 40 °C +5 °C to +30 °C +5°C to +10°C Thermoplastic flame retardant 120 x 90 x 32 mm Liquid Crystal, back lit 24 Hour 1 minute steps 15 minute steps Warm – 3 per day Auto, Standby Instant Warm / Cool 6 pin plate 868 MHz

8


ThermoPlus AS1, AS2 & PRT1 Programmable Room Thermostats Mains and battery powered programmable room thermostats designed for ease of use with a unique 3 button user interface. ThermoPlus allows a high and low temperature setting to be pre-programmed with simple user overrides available for the user. Despite the simple user interface ThermoPlus contains the latest TPI energy saving software and can make a significant contribution to saving energy. ThermoPlus has voltage free contacts and is ideal for use with combi boilers. Ÿ Simple 3 button operation Ÿ Colour coded, bright LED Warm / Cool display and Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ

Braille markings on the main override buttons Preset clock Automatic BST/GMT time change Preset or custom heating profiles Back lit LCD display Audible and tactile feedback Fixed hypothermia protection (PRT1) Frost protection setting

9


Specification AS1 & PRT1 AS1 is mains powered for applications where a permanent mains supply is readily available.

CONTACT RATING AC CONTACT TYPE

PRT1 is identical to the AS1 but with a fixed hypothermia setting of 15C.

SUPPLY

AS2 AS2 is battery powered for applications where no mains supply is readily available to operate the unit or an existing thermostat is being replaced. Additional features include 3 standard AA batteries, 2 years+ battery life and separate clock power back-up. Battery life is conserved by means of an 8 second auto power down mode to all indicator lights.

RESERVE BATTERY TYPE POLLUTION DEGREE DOUBLE INSULATED ENCLOSURE PROTECTION OPERATING TEMPERATURE RANGE TEMPERATURE CONTROL RANGE STANDBY TEMPERATURE CASE MATERIAL DIMENSIONS DISPLAY CLOCK DISPLAYED TIME ADJUSTMENTS SWITCHED TIME ADJUSTMENTS OPERATING PERIODS PER DAY PROGRAMME SETTINGS OVERRIDE MOUNTING

3 (1) Amps 230-240V Micro disconnection Voltage Free AS1/PRT1 – 230V AC 50Hz AS2 – 3 x AA (LR6) batteries Lithium battery Degree 2 Yes IP30 0 °C to 40 °C +5 °C to +30 °C +5°C to +10°C Thermoplastic flame retardant 120 x 90 x 32 mm Liquid Crystal, back lit 24 Hour 1 minute steps 15 minute steps Warm – 3 per day Auto, Standby Instant Warm / Cool AS1/PRT1 – 6 pin plate AS2 – Standard wall box fixing

10


ChannelPlus XL Series 2 Electronic Programmers

A range of electronic programmers that offer up to four independent channels and feature a large, easily read display and simple menu driven programming. Three and four channel models are made for multiple zone control with single and two channel models used with combi boiler systems and stored hot water systems. ! ! ! ! ! ! ! !

1, 2, 3 or 4 channels 24 hour or 7 day Back-lit LCD display Simplified menu driven programming Advance and boost on each channel Preset clock Automatic Winter / Summer time changes 5 year warranty

11


Specification CHANNELPLUS H47XL Programmer with 7 day setting over four independent channels. Designed for use with fully pumped central heating systems using four separate zone valves in addition to many other applications. CHANNELPLUS H37XL Programmer with 7 day setting over three independent channels. Designed for use with fully pumped central heating systems using three separate zone valves. Meets zoning requirements of Part L1 of the Building Regulations. CHANNELPLUS H37VXL The same as the H37XL but with volt free contacts CHANNELPLUS H27ZXL Two channel with 7 day programming and independent timing of zone 1 and zone 2. CHANNELPLUS H27XL Two channel with 7 day programming and independent timing of heating and hot water. CHANNELPLUS H21XL Two channel with 24 hour programming and independent timing of heating and hot water. CHANNELPLUS H17XL Single channel time switch with full 7 day programming CHANNELPLUS H11XL

CONTACT RATING CONTACT TYPE

SUPPLY POLLUTION DEGREE CLASS A SOFTWARE ENCLOSURE PROTECTIONS DOUBLE INSULATED OPERATING TEMPERATURE RANGE BATTERY LIFE CASE MATERIAL DIMENSIONS DISPLAY CLOCK DISPLAYED TIME ADJUSTMENTS SWITCHED TIME ADJUSTMENTS PROGRAMME OPTIONS

3 (1) Amps 230V AC Micro-disconnection Voltage free (not H37XL) 230V 50 Hz Degree 2 Type 1 Control IP30 Yes 0째 C to +40 째c Lithium Thermoplastic flame retardant 101 x 163 x 37 mm Back lit liquid crystal 24 hour or 12 hour AM/PM 1 minute steps 10 minute steps ON, OFF, All Day, Auto & Holiday

OPERATING PERIODS PER DAY 3 for each channel OVERRIDE (EACH CHANNEL) 1 or 2 hour boost 1 or 2 hour extension to ON period Instant advance MOUNTING 9 pin wall fixing plate

Single channel time switch with 24 hour programming. Voltage free contacts make both the H11 and H17 units ideal for combi boilers.

12


ChannelPlus H37XL Series 2 Electronic Programmers

A three channel programmer giving independent timing of each channel on a 7 day programme. Ideal for the control of two heating zones as well as hot water via separate thermostats and zone valves. ! ! ! ! ! ! ! !

Back-lit LCD display Preset clock Automatic Winter / Summer time changes Simplified menu driven programming Advance and boost on each channel Full 7 day operation Volt free version 5 year warranty

13


Specification ChannelPlus H37XL Series 2 Programmer with 7 day setting over 3 independent channels (e.g. Zones 1, 2 and 3 or hot water, heating 1 and 2) Designed for use with fully pumped central heating systems using three separate 2 port zone valves. Part L1 of the Building Regulations requires properties above 150 sq m floor space to have two separate heating zones. This is an ideal application for the H37XL. Also available: ChannelPus H37VXL The same as the H37XL but with volt free contacts

CONTACT RATING CONTACT TYPE

SUPPLY POLLUTION DEGREE ENCLOSURE PROTECTION DOUBLE INSULATED OPERATING TEMPERATURE RANGE BATTERY LIFE CASE MATERIAL DIMENSIONS DISPLAY CLOCK DISPLAYED TIME ADJUSTMENTS SWITCHED TIME ADJUSTMENTS PROGRAMME OPTIONS

3 (1) Amps 230V AC Micro-disconnection Voltage free (not H37XL) 230V 50 Hz Degree 2 IP30 Yes 0° C to 40 °c Lithium Thermoplastic flame retardant 101 x 163 x 37 mm Back lit liquid crystal 24 hour or 12 hour AM/PM 1 minute steps 10 minute steps ON, OFF, All Day, Auto & Holiday

OPERATING PERIODS PER DAY 3 for each channel OVERRIDE (EACH CHANNEL) 1 or 2 hour boost 1 or 2 hour extension to ON period Instant advance MOUNTING 9 pin wall fixing plate RATED IMPULSE VOLTAGE Cat 2 – 2500V POLLUTION DEGREE Degree 2 ENCLOSURE PROTECTION Flame retardant thermoplastic

14


ChannelPlus H47XL Series 2 Electronic Programmers

A four channel version of the ChannelPlus programmer for larger dwellings, featuring zone control of Hot Water and Heating as well as many other zoning applications including Underfloor heating. ! ! ! ! ! ! !

Full 7 day operation over 4 independent channels Back-lit LCD display Preset clock Automatic Winter / Summer time changes Simplified menu driven programming Advance and boost on each channel 5 year warranty

15


Specification ChannelPlus H47XL Series 2 A user friendly 4 channel programmer designed for domestic use, providing advanced, easily programmed features. The latest Building Regulations Domestic Heating Compliance Guide requires each heating zone that exceeds 150 sq m to have independent time and temperature control.

CONTACT RATING CONTACT TYPE SUPPLY POLLUTION DEGREE CLASS SOFTWARE ENCLOSURE PROTECTION DOUBLE INSULATED OPERATING TEMPERATURE RANGE BATTERY LIFE CASE MATERIAL DIMENSIONS DISPLAY CLOCK DISPLAYED TIME ADJUSTMENTS SWITCHED TIME ADJUSTMENTS PROGRAMME OPTIONS

3 (1) Amps 230V AC Micro-disconnection 230V 50 Hz Degree 2 Type 1 Control IP30 Yes 0° C to 40 °c Lithium Thermoplastic flame retardant 101 x 163 x 37 mm Back lit liquid crytal 24 hour or 12 hour AM/PM 1 minute steps 10 minute steps ON, OFF, All Day, Auto & Holiday

OPERATING PERIODS PER DAY 3 for each channel OVERRIDE (EACH CHANNEL) 1 or 2 hour boost 1 or 2 hour extension to ON period Instant advance MOUNTING 9 pin wall fixing plate RATED IMPULSE VOLTAGE Cat 2 – 2500V POLUTION DEGREE Degree 2 ENCLOSURE PROTECTION Flame retardant thermoplastic

16


CentaurPlus Series 2 Electronic time controls CentaurPlus single channel time switches and two channel programmers are highly popular and affordable with the latest Series 2 units now featuring an upgraded back lit display screen and incorporating an automatic GMT/BST clock. All models feature an industry standard six pin backplate which permits easy replacement/upgrade with the C11 and C17 controls being suited for use with combi boilers and the C21 and C27 versions for non combi boiler installations where a hot water cylinder is in use. Ÿ 24 hour and 7 day options Ÿ Up to 3 ON/OFF's a day Ÿ Hot water boost and central heating advance Ÿ Programme options: ON, OFF, ALL DAY or AUTO Ÿ Mains powered with battery back up Ÿ Standard wall plate – Simple to plug in and replace

17


Specification CentaurPlus C27 Two channel 7 day control allowing independent time control of central heating and hot water

CONTACT RATING CONTACT TYPE

SUPPLY POLLUTION DEGREE CLASS A SOFTWARE OPERATING TEMPERATURE RANGE BATTERY LIFE

CentaurPlus C21 Simple, low cost 24 hour version of the C27

CentaurPlus C17

CASE MATERIAL

Single channel, 7 day time control suitable for combi boiler applications, an extra heating zone or the pump on a solid fuel boiler.

DIMENSIONS DISPLAY CLOCK

CentaurPlus C11 DISPLAYED TIME ADJUSTMENTS SWITCHED TIME ADJUSTMENTS OPERATING PERIODS

CentaurPlus C21 CentaurPlus C11

• •

OVERRIDE

7 Day

24 Hour

Channel

• •

CentaurPlus C27 CentaurPlus C17

Two

Single Channel

Simple, low cost 24 version of the C17

• • • • MOUNTING

3 (1) Amps 230V AC Micro-disconnection Voltage free (C11 & C17 only) 230V AC 50Hz only Degree 2 Type 1 Control 0 °C to +40 °C Minimum 10 months continuous operation Thermoplastic flame retardant 84 x 150 x 29mm Back lit liquid crystal 12 Hour AM/PM Auto BST/GMT changeover 1 minute steps 10 minute steps C11 & C17 – 3 per day C21 & C27 – 3 per day for CH & 3 per day for HW C17 & C27 – Separate programmes possible for each day of the week C11 & C17 – 1 hour boost, 1 hour extension to ON period & Instant Advance C21 & C27 – 1 hour boost (HW only), 1 hour extension to ON period (HW only) & Instant advance (CH only) 6 terminal plug in wall plate

18


19


Specification CentaurPlus ZW The CentaurPlus ZW timeswitch and thermostat communicate using proven Z wave wireless technology with the installation highly suited for use with combi boilers. It is ideal as a system upgrade, in most cases requiring no wiring. The back plate on the CentaurPlus ZW is an industry standard 6 pin unit usually enabling a simple push fit replacement. The HRT4-ZW is battery powered and requires no disruptive wiring, enabling it to be positioned in the most efficient area of a room.

CONTACT RATING CONTACT TYPE SUPPLY POLLUTION DEGREE CLASS A SOFTWARE OPERATING TEMPERATURE RANGE BATTERY LIFE CASE MATERIAL

The thermostat incorporates the latest TPI energy saving software and Z wave wireless technology. It features a back lit display, conventional knob temperature adjustment, set temperature display and displays the actual room temperature at a touch of the dial. CentaurPlus ZW combined wireless room stat and timeswitch Ÿ Suitable for combi boilers Ÿ Volt free contacts Ÿ Automatic BST/GMT time change Ÿ Back lit display Ÿ Boost and Advance Ÿ Helps to meet Part L of Building Regs Ÿ Built in Z wave receiver Ÿ Industry standard 6 terminal wall plate Ÿ ZW wireless technology Ÿ TPI energy saving software Ÿ Clear backlit display Ÿ Temperature range 5-30°C Ÿ Battery operated for wire free installation

DIMENSIONS DISPLAY CLOCK

DISPLAYED TIME ADJUSTMENTS SWITCHED TIME ADJUSTMENTS OPERATING PERIODS PER DAY

OVERRIDE

MOUNTING TRANSMITTER FREQUENCY

3 (1) Amps 230V AC Micro-disconnection Voltage free 230V AC 50Hz only Degree 2 Type 1 Control 0°C to +40°C Minimum 10 months continuous operation Thermoplastic flame retardant 84 x 150 x 29mm Back lit liquid crystal 12 Hour AM/PM Auto BST/GMT changeover 1 minute steps 10 minute steps 3 per day (Separate programmes possible for each day of the week) 1 hour boost, 1 hour extension to ON period & Instant Advance 6 terminal plug wall plate 868MHz

HRT4-ZW ROOM THERMOSTAT POWER SUPPLY 2 x AAA alkaline batteries OPERATING TEMPERATURE 0°C to +40°C RANGE TEMPERATURE RANGE 5°C to 30°C CASE MATERIAL Thermoplastic flame retardant DIMENSIONS 86 x 86 x 36.25mm RATED IMPULSE VOLTAGE Cat 1 – 1500v ENCLOSURE PROTECTION Ip30 TRANSMITTER FREQUENCY 868MHz DESIGN STANDARD EN60730 – 2-9

20


ServicePlus Series 2 Service Interval Programmers ServicePlus is a range of programmers and time switches developed to facilitate compliance with the Gas Safety (installation and Use) Regulations 1998. Although not intended to replace the normal servicing regime, ServicePlus can act as a supplementary reminder to enabling compliance. Features an upgraded back lit display screen and incorporates an automatic GMT/BST clock. Ÿ Service interval safety check clock Ÿ Can fully or partially shut down the system once a service period is overdue Ÿ Service period is set by installer using unique key code Ÿ Facilitates compliance with Gas Safety Regulation 36 Ÿ Building Regs Part L compliant

21


Specification The ServicePlus service interval timer range is based on the popular Centaurplus range of domestic central heating programmers and timeswitches. All the functions and facilities available in the CentaurPlus range are also available in the equivalent ServicePlus model. E.G. S27R is based on C27, S17R is based on C17 etc. The ServicePlus range of programmers and time switches are designed to carry out a full or partial boiler shutdown once the servicing date has become overdue. The Installer can set the ServicePlus so that either a full shutdown will occur after a 28 day warning period of the boiler service becoming due or partial shutdown can be selected where a 15 minute period of heating and hot water will occur every hour. These 15 minute periods will occur every hour but never consecutively from one hour to the next. If programmed on installation, the 15 minute 'On' periods will reduce the effectiveness of the heating system so that it becomes uncomfortable for the occupier without it providing no heating at all. This should have the effect of encouraging the householder to call the service engineer to check the system.

CONTACT RATING CONTACT TYPE

SUPPLY POLLUTION DEGREE CLASS A SOFTWARE OPERATING TEMPERATURE RANGE BATTERY LIFE CASE MATERIAL DIMENSIONS DISPLAY CLOCK DISPLAYED TIME ADJUSTMENTS SWITCHED TIME ADJUSTMENTS OPERATING PERIODS PER DAY

(For more detailed information on these products, please refer to CentaurPlus Series 2)

S27R 7 day programmer S21R 24 hour programmer

OVERRIDE

S17R 7 day timeswitch S11R 24 hour timeswitch

CentaurPlus S21 CentaurPlus S11

• •

Minimum 10 months continuous operation Thermoplastic flame retardant 84 x 150 x 29mm Back lit liquid crystal 12 Hour AM/PM 1 minute steps 10 minute steps S11 & S17 – 3 per day S21 & S27 – 3 per day for CH & 3 per day for HW S17 & S27 – Separate programmes possible for each day of the week S11 & S17 – 1 hour boost, 1 hour extension to ON period & Instant Advance S21 & S27 – 1 hour boost (HW only), 1 hour extension to ON period (HW only) & Instant advance (CH only) 6 terminal plug wall plate

7 Day

24 Hour

Channel

• •

CentaurPlus S27 CentaurPlus S17

Two

Single Channel

MOUNTING

3 (1) Amps 230V AC Voltage free (S11 & S17 only) with optional mains switched supply 230V AC 50Hz only Degree 2 Type 1 Control 0°C to +40°C

• • • •

22


425 Series Electro-mechanical Programmers 425 series mechanical programmers are the simplest way to control hot water and central heating in the home. Ÿ Simple to use with easily understood settings adjusted in

seconds Ÿ Rotating 24 hour dial and tappet arrangement Ÿ Easy to install using a nine pin backplate Ÿ Advance control to allow manual override ON or OFF Ÿ Programme options: ON, OFF, All Day or Auto

23


Specification 425 DIADEM

425 TIARA & DIADEM

This twin circuit, hot water and central heating programmer, with indicator lights, has 16 programmes available for fully pumped systems, including independent programming of heating and hot water and 10 programmes for gravity hot water / pumped heating systems. The Diadem is ideal for gravity systems and fully pumped systems with zone valves.

425 TIARA The Tiara has all the capability and features of the 425 Diadem, but without the indicator lights. The Tiara is ideally suited for both gravity systems and fully pumped systems with either mid-position or zone valves.

CONTACT RATING CONTACT TYPE

MOTOR

POWER CONSUMPTION DIRT PROTECTION MOISTURE PROTECTION ENCLOSURE PROTECTION MAXIMUM OPERATING TEMPERATURE DIAL SETTING

DIMENSIONS MOUNTING

425 CORONET

CONTACT RATING CONTACT TYPE

The 425 Coronet is particularly suitable for combi boiler systems, warm air systems and extra zone control.

• •

Indicator Lights

• •

Immersion Heaters

• • •

Independent CH / HW

• • •

Gravity HW

• • •

Pumped Systems

• • •

Combi Boilers

ON / OFF twice a day

ON All Day

• •

Permanent ON/OFF

425 Coronet

Twin Circuit

Single Circuit

MOTOR

425 Tiara

2 ON, 2 OFF Tappets Min. ON/OFF period 45 mins 152mm x 107mm x 39mm 9 Pin wall fixing plate

425 CORONET

A single circuit timeswitch for straight forward, accurate time control.

425 Diadem

Double circuit 6 (2.5) Amps 230V AC Micro-disconnection changeover Voltage Free Synchronous 230V 50Hz Double Insulated 2.5W Normal Situations Ordinary Ip20 +55°C

POWER CONSUMPTION DIRT PROTECTION MOISTURE PROTECTION ENCLOSURE PROTECTION MAXIMUM OPERATING TEMPERATURE DIAL SETTING

• DIMENSIONS MOUNTING

Single circuit 13 (6) A 230V AC Micro-disconnection changeover Voltage Free Synchronous 230V 50Hz Double Insulated 2.5W Normal Situations Ordinary Ip20 +55°C 2 ON, 2 OFF Tappets Min. ON/OFF period 45 mins 152mm x 107mm x 39mm 9 Pin wall fixing plate

24


HRT4-ZW and HRT4-B Electronic Room Thermostats Wireless or wired, this range of purpose designed room thermostats from Horstmann offer the latest energy saving control technology combined with established Horstmann design and manufacturing expertise, making them suitable for use in most types of heating system. They are also perfect partners for use with Horstmann Programmers and Zone valves. Ÿ Wireless or wired (battery operated) versions Ÿ TPI temperature control software Ÿ Clear backlit digital display Ÿ Temperature range 5-30°C Ÿ Easy to install and use

25


Specification HRT4-ZW with ASR-ZW receiver Wireless Z-wave electronic room thermostat and ASRZW receiver with TPI energy saving software – avoids disruptive and time consuming wiring – compatible with most heating systems. With proven Z-wave wireless technology using the 868.42MHz operating frequency, the thermostat unit features a constant RF status display with its receiver being mains powered with volt free contacts.

HRT4-B The HRT4-B is a wired battery operated room thermostat with TPI energy saving software – for use with new installations or as a replacement for existing room thermostats.

HRT4-ZW POWER SUPPLY POLLUTION DEGREE TEMPERATURE ACCURACY TEMPERATURE RANGE OPERATING TEMPERATURE RANGE CASE MATERIAL DIMENSIONS RATED IMPULSE VOLTAGE ENCLOSURE PROTECTION DESIGN STANDARD TRANSMITTER FREQUENCY

2 x AAA alkaline batteries Degree 2 +/- 0.5°C 5 °C - 30 °C 0° C - 40 °C Thermoplastic flame retardant 86 x 86 x 36.25mm Cat 2 – 2500v IP30 EN60730 – 2-9 868 MHZ

ASR-ZW The HRT4-B has 3 amp volt free change over contacts – making it ideal for use with combi boilers as well as conventional mains operated equipment.

POWER SUPPLY CONTACT TYPE

Designed to look good, these thermostats will out perform many older styles of thermostat and can often produce savings in the order of 10% over and above those achieved by traditional units using older technology.

CONTACT RATING POLLUTION DEGREE OPERATING TEMPERATURE RANGE CASE MATERIAL

The TPI settings are adjustable for Gas, Oil and Electric systems and the display shows 1°C resolution, heating ON symbol, target and actual temperatures at the touch of the dial and an energy saving back light that switches off after 7 seconds.

DIMENSIONS RATED IMPULSE VOLTAGE ENCLOSURE PROTECTION

Available in wireless and wired versions – for new and replacement situations – there is a Horstmann thermostat to suit most installations.

HRT4-B

The wireless version employs the latest Z-wave radio frequency (RF) technology resulting in a highly reliable and trouble free wireless connection with minimal setting up procedures.

CONTACT TYPE

Thermostat battery life is in excess of two years using 2 standard AAA batteries which are supplied. A battery low indication tells the user when the batteries need changing.

CONTACT RATING POLLUTION DEGREE TEMPERATURE ACCURACY TEMPERATURE RANGE CASE MATERIAL

POWER SUPPLY

DIMENSIONS RATED IMPULSE VOLTAGE ENCLOSURE PROTECTION DESIGN STANDARD

230 V AC 50 Hz Micro disconnection Voltage free 3 (1) Amps 230 V AC Degree 2 0° C - 40 °C Thermoplastic flame retardant 86 x 86 x 36.25mm Cat 2 – 2500v IP30

2 x AAA alkaline batteries Micro disconnection Voltage free changeover 3 (1) Amps 230 V AC Degree 2 +/- 0.5°C 5 °C - 30 ° Thermoplastic flame retardant 86 x 86 x 36.25mm Cat 2 – 2500v IP30 EN60730 – 2-9

26


HRT4-A, HFT4 and HTT4 Mains Operated Electronic Room Thermostats This range of purpose designed room thermostats from Horstmann offer the latest energy saving control technology combined with established Horstmann design and manufacturing expertise. This makes them suitable for use in most types of heating system that respond to a 230 volt mains electrical On/Off signal. They are also perfect partners for use with Horstmann Programmers and Zone valves. Ÿ 230 volt mains operation Ÿ TPI temperature control software Ÿ Standard, Frost and Tamperproof versions Ÿ Easy to install and use

Designed to look good, these thermostats will out perform many older styles of thermostat and can often produce savings in the order of 10% over and above those achieved by traditional units using older technology. The temperature control accuracy of +/- 0.5°C and different TPI settings – for Gas, Oil and Electric systems – will reduce the temperature swing that normally occurs with older style thermostats. As a consequence these thermostats will help to save energy as the control algorithm allows the boiler to operate in condensing mode for longer periods.

27


Specification HRT4-A – Room Thermostat Mains powered, electronic unit with TPI technology for new and replacement installations. Temperature setting range 5-30 °C

POWER SUPPLY CONTACT RATING CONTACT TYPE POLLUTION DEGREE TEMPERATURE ACCURACY TEMPERATURE RANGE

HTT4 – Tamper proof Room Thermostat A tamper proof version of the HRT4-A for use in public areas or other situations where subsequent temperature adjustment is not required/desirable. Ÿ Internal setting dial Ÿ Temperature setting range 10-30°C

CASE MATERIAL DIMENSIONS RATED IMPULSE VOLTAGE ENCLOSURE PROTECTION DESIGN STANDARD

230v 50Hz 3 (1) Amps 230V AC Micro-disconnection Degree 2 +/- 0.5°C (at 21 °C with 0.5 amp load) HRT4-A – 5-30°C HTT4 – 10-30°C HFT4 – 0-20°C Thermoplastic flame retardant 86 x 86 x 36.25mm Cat 2 – 2500v IP30 EN60730 – 2-9

HFT4 – Frost Thermostat Electronic mains operated frost protection thermostat. Ensures heating will switch on whenever frost conditions are detected. Ÿ Internal setting dial Ÿ Temperature setting range 0-20°C

28


HCT2 Hot Water Cylinder Thermostat This cylinder thermostat is fitted to the hot water cylinder to ensure that water temperature is controlled to a safe temperature whilst also saving energy by stopping uncontrolled heating of the hot water. This type of cylinder stat is intended for use as part of a fully pumped heating and hot water system in conjunction with motorised zone valves a room thermostat and a two channel central heating programmer. Ÿ 230V mains operation Ÿ Adjustable temperature range 20°C to 90°C Ÿ 16 Amp changeover (S.P.D.T.) contacts Ÿ Switching differential of approximately 8°C Ÿ Bimetallic sensor system

29


Specification Cylinder Thermostat – HCT2 With an adjustable temperature range of between 20°C to 90°C, the Horstmann cylinder thermostat is suitable for mounting on either domestic hot water cylinders or large heating pipes.

CONTACT CONFIGURATION OPERATING VOLTAGE SWITCH CURRENT TEMPERATURE RANGE SWITCHING DIFFERENTIAL ENCLOSURE PROTECTION SENSOR SYSTEM DIMENSIONS

SPDT 220/240V 50/60Hz 250V AC 16 Amps maximum +20 °c to +90 °C +8 °C Approx IP40 Bimetallic 105 x 70 x 53 mm

30


ZonePlus Z Series Motorised Valves A range of motorised valves that combine proven controls technology with the latest Horstmann design features, permitting easy installation and maintenance. There are 3 models in the range: 22mm and 28mm 2 port spring return valves and a 22mm 3 port mid position diverter valve. 타 Easily replaceable actuator 타 Industry standard fittings and wiring 타 Extra long 1.4 metre cable 타 Hansen Class F Synchron motor

31


Specification ZonePlus Z322

CONTACT AND POWER SUPPLY POWER CONSUMPTION LEAD SUPPLIED

22mm mid-position diverter valve complete with compression fittings.

ZonePlus Z222 22mm spring return zone valve with auxiliary switch complete with compression fittings.

ZonePlus Z228 28mm spring return zone valve with changeover auxiliary switch complete with compression fittings.

MAXIMUM AMBIENT TEMPERATURE MAXIMUM FLUID TEMPERATURE MAXIMUM DIFFERENTIAL PRESSURE MAXIMUM STATIC PRESSURE MATERIALS BALL COVER VALVE BODY PIPE FITTING SIZE

2 Port ZonePlus Z222

3 Port

22mm

• •

ZonePlus Z228 ZonePlus Z322

28mm

3 Amp 250V AC 230V 50Hz 5W 1.4 Metre, Industry Standard colour coding. 50°C 88°C 0.5 bar 8.6 bar

Ethylene Propylene Dio Mono (EPDM) Thermoplastic Brass Z222 & Z322 – 22mm compression (supplied) Z228 – 28mm compression (supplied)

32


Electrisaver Electronic Timer The Electrisaver is a simple push button electronic timer that saves energy by remembering to switch off an appliance when you might forget! Suitable for loads up to 3kW, Electrisaver is a perfect boiler override or extension timer and can also be used on electrical equipment such as panel heaters, immersion heaters, heated towel rails and oil filled radiators. Flush or surface mounting 타 Wiring is simple with easy access terminals 타

33


Specification Electrisaver

CONTACT RATING

Simply press the boost button and walk away, safe in the knowledge that if you forget, Electrisaver won't! The 3kW rating makes Electrisaver suitable for use with immersion heaters with a range of applications in shops, offices, schools, church halls, student accommodation and all around the home. ŸOil fired radiators ŸTowel rails

SUPPLY POLLUTION DEGREE ENCLOSURE PROTECTION SHOCK PROTECTION LIVE PARTS OPERATING TEMPERATURE RANGE DIMENSIONS

ŸBoiler override ŸPanel heaters

There are three Electrisaver models which offer preset time periods. ŸE15 - 15-60 minutes ŸE30 - 30-120 minutes ŸE246 - 2-6 hours

MOUNTING

13 Amps 230V AC Suitable for loads up to 3kW 230V 50Hz Degree 2 IP30 Class 1 Enclosed 0°c to 35°C 87mm x 87mm x 16mm (Flush mounting) or 51mm (Surface mounting) Single gang moulded box (Min. 35mm deep, not supplied)

34


Electronic 7 Series 3 Immersion Heater Control The Horstmann Electronic 7 is the digital equivalent to the renowned Horstmann Economy 7 Quartz timer and is designed for use with Economy 7 and other more recent cheap rate tariff arrangements. Where hot water is heated by off peak electricity it is important that the immersion heater controller offers ease of use coupled with the most efficient performance. This is where the Horstmann Electronic 7 Series 3 controller comes into its own. Ÿ Compatible with most cheap rate or off peak tariff

Ÿ Ÿ Ÿ Ÿ Ÿ

structures, the Electronic 7 is fully interchangeable with all past and present Horstmann Economy 7 controllers Built in clock – automatic Summer / Winter time change Up to three off peak settings per 24 hours Programmable and manual boost Programme security feature Suitable for use with single, dual or twin element immersion heaters

35


Specification Electronic 7 Series 3 The Electronic 7 is designed to control one or two 3kW immersion heaters, utilizing off peak electricity tariffs to provide a tank full of hot water each morning. Additional off peak settings are available to take advantage of the latest off peak tariff arrangements. A boost button is provided to top up the hot water if supplies are running low and an automatic boost setting to provide a pre-programmed daily boost is also available. The Electronic 7 Series 3 is interchangeable with previous Economy 7 controllers using the standard size Economy 7 wall box and plug in connectors. A lithium battery provides more than adequate back up to maintain time and programme settings in the event of a power failure.

CONTACT RATING

CONTACT TYPE

SUPPLY POLLUTION DEGREE MOISTURE PROTECTION ENCLOSURE PROTECTION SHOCK PROTECTION LIVE PARTS OPERATING TEMPERATURE RANGE BATTERY RESERVE

DIMENSIONS

CLOCK

PROGRAMME OPTIONS

BEAB APPROVED

13 Amps 230V AC Suitable for immersion heaters up to 3kW Micro-disconnection on control Disconnection to immersion heaters on double-pole rocker switch 230V 50Hz Degree 2 Normal situations Ordinary IP30 Class 1 Enclosed 0째c to 35째C Approximately 2 years total power disconnection 170 x 115 x 60 mm (Excluding rocker switch) AM/PM Indication Winter/Summer indication OFF PEAK - Up to 3 On/Off time periods BOOST Programmable automatic boost and one hour manual boost Yes

36


Economy 7 Quartz Immersion Heater Control Designed for use with Economy 7 off peak rate overnight electricity, the Economy 7 Quartz is the standard by which all other water heating controls are judged and is the alltime best seller in water heating controls. Ÿ Quartz controlled within 10 minutes a year Ÿ Rechargeable battery keeps time during power

interruptions Ÿ Summer and winter time settings instantly visible Ÿ Large terminals and back box for easy installation Ÿ Indicator lights show whether on-peak or off-peak power

is being used Ÿ Up to 60 minute boost means extra hot water at any time Ÿ Industry standard wall box and connections

37


Specification Economy 7 Quartz A proven, reliable and accurate unit, the Economy 7 Quartz is easy to install and set, providing a tankful of hot water to start each day utilizing Economy 7 off peak rate overnight electricity. The manual boost timer provides extra hot water in the day time – should it be needed.

CONTACT RATING

CONTACT TYPE

E 7 Quartz 2 Hour The E7 Quartz 2 hour model has the same specification as the Economy 7 Quartz but with 0 – 120 minutes boost timer.

SUPPLY POLLUTION DEGREE MOISTURE PROTECTION ENCLOSURE PROTECTION SHOCK PROTECTION LIVE PARTS IMPULSE RATING OPERATING TEMPERATURE RANGE BATTERY RESERVE DIMENSIONS CLOCK

PROGRAMME OPTIONS

BEAB APPROVED

13 Amps 230V AC Suitable for immersion heaters up to 3kW Micro-disconnection on control Disconnection to immersion heaters on double-pole rocker switch 230V 50Hz Degree 2 Ordinary IP30 Class 1 Enclosed 4000V 0°c to +35°C 150 hours 170 x 115 x 60 mm (Excluding switches) AM/PM Indication Winter/Summer indication OFF PEAK – Adjustable between 4½ & 7 hours BOOST – Economy 7 Quartz – 0-60 minutes E7 Quartz 2 Hour – 0120 minutes Yes

38


BX2000 Water Heating Boost Control This simple boost control is intended for use with electric water heating systems where the immersion heater(s) are controlled by the Electricity Company's Radio Teleswitch, Radio Telemeter or Tariff time switch. The BX2000 allows the user to 'top up' the hot water if extra supplies are needed during the day time with the main water heating taking place overnight using off peak electricity. 타 Makes the most effective use of the latest cheap-rate

tariff structures, electronically 타 1 hour or 2 hour boost 타 Always gives priority to off-peak supply

39


Specification BX2000 Automatically cancels any boost that has been selected prior to the off-peak supply becoming available Ÿ Indicator lights show when 'boost' or 'off-peak' are operational Ÿ Incorporates two double pole switches: one for 24 hour supply: one for off-peak (cheap rate) supply Ÿ Accepts all incoming and outgoing wiring for single, dual or two separate 3kW immersion heater applications

CONTACT RATING

Ÿ

CONTACT TYPE

POWER SUPPLY POLLUTION DEGREE ENCLOSURE PROTECTION SHOCK PROTECTION LIVE PARTS OPERATING TEMPERATURE RANGE TIME PERIOD DIMENSIONS BRITISH STANDARDS

13 Amps 230V AC Suitable for immersion heaters up to 3kW Disconnection to immersion heater on double-pole switch 230 V 50Hz Degree 2 IP30 Class 1 Enclosed 0 °C to 35 °C 1 or 2 hours 170 x 115 x 62 mm Designed to meet BSEN 60730-2-7

40


E7BX Water Heating Boost Control This simple boost control is intended for use with electric water heating systems where the immersion heater(s) are controlled by the Electricity Company's Radio Teleswitch, Radio Telemeter or Tariff time switch. The E7BX allows the user to 'top up' the hot water if extra supplies are needed during the day time with the main water heating taking place overnight using off peak electricity. 타 Designed to accept wiring from both 24 hour and off peak

circuits 타 Adjustable 0-120 minute run-back boost timer 타 Simple to install and use

41


Specification E7BX Ÿ Ÿ Ÿ Ÿ Ÿ

Simple to install and use Boost period adjustable between 0 and 120 minutes Neon indicator shows when boost timer is running Can be used with one or two immersion heaters Suits earth-leakage circuit breaker installations

CONTACT RATING

CONTACT TYPE

POWER SUPPLY POLLUTION DEGREE ENCLOSURE PROTECTION SHOCK PROTECTION LIVE PARTS OPERATING TEMPERATURE RANGE TIMER BOOST DURATION DIMENSIONS BRITISH STANDARDS

13 Amps 230V AC Suitable for immersion heaters up to 3kW Disconnection to 'off peak' immersion heater on double-pole switch 230 V 50Hz Degree 2 IP30 Class 1 Enclosed 0 °C to 35 °C 0-120 minutes 170 x 115 x 56 mm Designed to meet BSEN 60730-2-7 BEAB APPROVED

42


Electric Water Heating Controls - Schematic System Diagrams These diagrams show the schematic installation wiring for each of the Horstmann electric water heating controls E7 & E7Q Single element immersion heater installation consumer unit

Immersion heater circuit

E7 & E7Q Twin element immersion heater installation consumer unit

Immersion heater circuit

Boost

Electricity Company's equipment

E7 & E7Q Dual element immersion heater installation consumer unit

Night Rate

Electricity Company's equipment

Immersion heater circuit

Night Rate

BX2000 & E7BX Single element immersion heater installation 24 hr consumer unit

Electricity Company's equipment

Boost

Off-peak consumer unit

Electricity Company's equipment

BX2000 Twin element immersion heater installation

E7BX Twin element immersion heater installation 24 hr consumer unit

24 hr consumer unit

Boost Double pole isolator

Electricity Company's equipment

Electricity Company's equipment Night Rate

Night Rate Off-peak consumer unit

Boost

Off-peak consumer unit

Installation and connection must be carried out by a suitably qualified person and in accordance with the current edition of the IET wiring regulations 43


Internal Wiring Diagrams Programmers and Timeswitches These diagrams are intended for guidance only and show the switched outputs for each model. Full system wiring diagrams are supplied with each set of installation instructions.

ChannelPlus H11XL / H17XL

3

4

5

ChannelPlus H37XL

N

L

1

2

3

N

L

ON

MAINS SUPPLY

OFF

ON

CH ZONE 1

4

5

L

1

OFF

ON

CH ZONE 2

2

3

OFF

HW

4

N

L

ON

COM

ON

ON

6

L

1

2

3

4

5

N

L

ON

COM

ON

COM

ON

MAINS SUPPLY

CH ZONE 1

6

CH ZONE 2

COM

HW

When used to control MAINS VOLTAGE SYSTEMS Terminals L,2,4 and 6 should be electrically linked by means of a suitable piece of sleeved conductor When used to control LOW VOLTAGE SYSTEMS these links MUST NOT be fitted

5

6

L

1

2

3

4

COM ON

230V

50Hz

COMM OFF

ON

The CentaurPlus ZW has voltage free contacts. A link L-2 is required for mains voltage applications

CentaurPlus C11 / C17

230V

5

CentaurPlus C17-ZW

MAINS SUPPLY

N

4

N

N E

3

6

ChannelPlus H47XL

N

2

ChannelPlus H37VXL

E

E

1

CH OFF

TIMED OUTPUT

L

CH ON

MAINS SUPPLY

OFF

N

HW OFF

ON

6

HW ON

L

2

LIVE

N

1

NEUTRAL

L

EARTH

E

N

ChannelPlus H21XL / H27XL / H27ZXL

L 50HZ

1

2

3

COMM OFF

CentaurPlus C21 / C27

4 ON

N 230V

L 50HZ

1

2

3

4

HW OFF

CH OFF

HW ON

CH ON

Installation and connection must be carried out by a suitably qualified person and in accordance with the current edition of the IET wiring regulations 44


425 Tiara / Diadem

E

N

L

1

N

L

ON

MAINS SUPPLY

2

3

4

OFF

ON

TIMED OUTPUT

5

425 Coronet

E

OFF

L

230V

60Hz

1

2

L

N

L

1

2

3

4

5

6

ON

MAINS SUPPLY

TIMED OUTPUT

ServicePlus S11R & ServicePlus S17R

N

N 6

3

ServicePlus S21R & ServicePlus S27R

N

4

MAINS LIVE TO COMM IN BOILER

OFF TIMED OUTPUT

ON

230V

L

1

2

3

4

50HZ

HW OFF

CH OFF

HW ON

CH ON

Thermostats These diagrams are intended for guidance only and show the switched outputs for each model. Full system wiring diagrams are supplied with each set of installation instructions.

Programmable Room Thermostats C-Stat B

C-Stat M

CALL

COMMON

1

1

2

3

2

3

4

L

N 230V MAINS SUPPLY

4 CALL FOR HEAT

CALL FOR HEAT

C-Stat ZW Receiver

ThermoPlus AS1 / PRT1

Internal Electronics

N 230V

L 50Hz

1

2

3

COMM OFF

4

N

ON

230V

L 50HZ

1

2 COMM

3

4 ON

Installation and connection must be carried out by a suitably qualified person and in accordance with the current edition of the IET wiring regulations 45


ThermoPlus AS2

ThermoPlus AS2-RF Receiver

1 LIVE (LINE)

4.5V

2 LOAD (HEAT)

N

L

1

2

3

4

3 NOT USED 230V

4 N (PARKING)

50Hz

COMM OFF

ON

The reciver has Voltage Free contacts. A link between Live and terminal 2 is required for mains Voltage applications

CentaurStat 1/7

HCT2 - Cylinder Stat

4

N (PARKING)

3

LOAD (COOL)

2

LOAD (HEAT)

1

L (LINE)

COM

2

1

SAT

CALL

Room Thermostats HRT4 - A / HTT4 / HFT4

1

2

3

HRT4-B

4

230V L 50Hz N Mains supply E

Switched live (call)

COMMON 1

2

3

4 CALL FOR HEAT

HRT4-ZW Receiver

HRT3

Internal Electronics

N 230V

L 50Hz

1

2

3

COMM OFF

4

4

N

3

LOAD (HEAT)

2

DO NOT USE

1

L (LINE)

ON

The receiver has Voltage Free contacts A link between live and terminal 2 is required for mains voltage applications.

Installation and connection must be carried out by a suitably qualified person and in accordance with the current edition of the IET wiring regulations 46


TPI energy saving software

where it is used – the benefits Time Proportional Integral (TPI) energy saving software is key to the performance of thermostats in a number of Horstmann's central heating controls – notably the HRT range of room thermostats, C-Stat programmable room thermostats, the CentaurPlus ZW combined wireless room 'stat and time-switch and the ThermoPlus range of easy-to-use programmable room thermostats. TPI has proven energy saving features that have been independently assessed (by TACMA) to save the householder up to 10% annually on fuel costs. So, how does it work? Traditionally, room stats use either mechanical bellows or thermally operated switches. These are much less accurate in maintaining the room temperature at the 'set point' as they produce fairly large swings of temperature caused by the differential between the on and off switch point. In turn, this causes the boiler to fire inefficiently and often over-heat the room. A thermostat controlled by TPI software makes a series of precise calculations once it has entered the control or proportional band. When set to 6 cycles per hour the software will calculate the amount of heat needed during each 10 minute period and switch the boiler on for a proportion of that 10 minutes to maintain the set temperature. This stops the wide fluctuations in temperature that can occur with conventional thermostats. The TPI software then 'fine tunes' the calculations to constantly review performance and carry out further, fine, adjustments if necessary. When used with a condensing boiler, the TPI thermostat will help to save energy as the control algorithm allows the boiler to operate in condensing mode more consistently compared to older types of thermostat. This effect is achieved by keeping the return water temperature below the critical 56ºC needed for the boiler to operate in condensing mode for longer.

Thermostat comparison set at 21 °C 25 °C

BOILER ON TIMES

24 °C 23 °C

20

30

40

50

22 °C

60

Example 1: TPI set to 6 cycles per hour giving 50% load every 10 minute cycle

Temperature

10

0

21 °C HRT4-B running TPI 6

20 °C 19 °C 18 °C

BOILER ON TIMES

17 °C 16 °C 15 °C

0

10

20

30

40

50

60

Example 2: TPI set for 6 cycles per hour giving approximately 25% load very 10 minute cycle

Time (1 hour intervals)

Actual test results of 3 common mechanical room thermostats and the Horstmann HRT4-ZW room thermostat

47


Optimum start

C-Stat programmable room thermostat The Horstmann C-Stat is an electronic programmable room thermostat that combines time and temperature control in a stylish design that features simple, menu driven programming and a clear, back lit user interface.Among its many new features the C-Stat features an (optional) optimum start function. C-Stat also uses the latest TPI energy saving software for accurate temperature control. TPI is highly accurate and sensitive and can produce savings of as much as 10% annually* on central heating fuel costs. Models in the range feature 24 hour and 7 day programming with up to six temperature settings per day. The intuitive interface ensures they are easy to set up and use. The Optimum Start feature: This (optional) setting will allow the C-Stat to anticipate the next set temperature and switch on the central heating up to 2 hours in advance to ensure the set room temperature has been reached by the time it is due to take effect. Optimum Start

As a consequence the 'switch on' time could take place anywhere between 2 hours and zero minutes before the set time.

21

It is assumed that the heating can increase at a rate of 2°C per hour. Therefore, the maximum extent of this setting is that it can switch on up to 2 hours before the set temperature and raise the temperature by 4°C (with an assumed warm up rate of 2°C per hour).

Room Temperature

20 19 18 17 16 15 2

The 2 hour optimisation period and the 2°C per hour assumed temperature rise are non adjustable.

1.5

1

0.5

0

Hours before next temperature setting of 20 °C

The optimisation process will be cancelled if any overrides are used during the 2 hour period of operation. Benefits For units without an optimum start or delayed start feature, normal practice is to set the heating to come on approximately 1 hour before it is expected to be up to the set room temperature. For example, if a householder gets up at 6.30am, the heating will typically be set to come on at 5.30am to allow the house to be warm by 6.30am. The benefit of the optimum start feature is that the heating switch on time is calculated based on the temperature sensed 2 hours before the set time. The actual switch on time is then delayed as long as possible whilst still achieving the correct required temperature at the set time. In mild weather conditions, the start time will be delayed until the last possible moment achieving considerable (energy) savings over a fixed 1 hour warm up time. By contrast, in exceptionally cold weather conditions, the heating may be brought on up to 2 hours before the time required but this will not be normal (in the UK) and savings should outweigh the extra heating needed in exceptionally cold conditions. The added benefit of optimum start is that comfort conditions will be improved as the heating will be better controlled and less likely to overheat the house on mild mornings.

48


Heating Programmer Replacement and Wiring Guide

If you’re replacing a central heating programmer you could just fit what was there before, or go one better and fit Horstmann. This handy guide shows you which of our programmers, from a straightforward electro mechanical unit to a 2 channel 7 day electronic programmer, is the perfect match. Often you can simply plug in without even having to rewire. Whichever one you select, you can be sure that it’s well designed, beautifully engineered and bang up to date with the latest spec. You won’t be replacing it in a hurry.

24 hour

7 Day

CentaurPlus C11

CentaurPlus C17

ChannelPlus H11XL

ChannelPlus H17XL

CentaurPlus C21

CentaurPlus C27

ChannelPlus H21XL

ChannelPlus H27XL

Using the Guide First locate the existing programmer or timeswitch in the left hand column of the Programmer Compatibility Guide. Then simply follow the colour coded line over to the far right to find the recommended Horstmann replacement. The colour of the line indicates if it is a direct plug-in replacement or not. Where a 24 hour programmer or timeswitch is recommended, its 7 day equivalent can be used and fitted in the same way. Wiring Comparison Table Before removing any existing programmer it is essential to make a note of wire colours, terminal positions and numbers in relation to the existing backplate. The charts only include programmers or timeswitches where wiring changes are necessary when fitting our recommended replacement. Where a direct plug-in replacement is available or where terminal connections do not change, the appropriate replacement is shown on the Programmer Compatibility Guide. For clarity the Compatibility Guide recommends replacements which are 24 hour programmers/timeswitches. All cases where a 24 hour programmer is stated as the recommended replacement, it’s 7 day equivalent can be used and fitted in the same way.

Download our wiring guide here

Apple QR code

Android QR code

Installation and connection should only be carried out by a suitably qualified person and in accordance with the current edition of the IET wiring regulations. The information contained in this manual is intended for guidance only and is believed to be correct. Secure Controls (UK) Limited can accept no liability for any errors or omissions and reserve the right to make changes at any time without notice.

49


Programmer Compatibility Guide

DANFOSS RANDALL

DRAYTON/ LP 111 ACL/INVENSYS LP 112 LP 241 LP 522 LP 711 LP722 LS 111 LS 112 LS 241 LS 522 LS 711 LS 722 FP MP TC Switchmaster 300 Switchmaster 320/350 Switchmaster 400 Switchmaster 600 Switchmaster 805 Switchmaster 900 Switchmaster 905 Switchmaster 9000/9001 Switchmaster 980 Switchmaster Sonata SM1 SM2 Tempus 1 Tempus 2

Common Time Base

Programmer

Mini-Programmer

Timeswitch

1.5 Circuits

Replacement and re-wiring of backplate required*

Two Circuit

Single Circuit

Two Channel

Single Channel

7 day

5/2 day

24 Hour

Model

102 102E 102E5 102E7 103 103E 103E5 103E7 3001 3002 3060 4033 3020P 911 917 922 971 972 CP15 CP75 CP715 FP15 FP75 FP715 FP975 MP15 MP75 SET1/SET1E SET2/SET2E SET3E SET3M SET4 SET5 TS15 TS75 TS715 TS975

Electronic

Manufacturer

Direct plug in replacement with simple wiring changes*

Electro-mechanical

Direct plug in replacement

Replace backplate but terminal connections remain the same

*Please see wiring comparison tables located in this guide

Recommended Replacement 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C27 or ChannelPlus H27XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C17 or ChannelPlus H17XL 425 Coronet or ChannelPlus H11XL 425 Diadem/Tiara or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C21 CentaurPlus C27 CentaurPlus C27 CentaurPlus C21 CentaurPlus C27 CentaurPlus C27 ChannelPlus H27XL CentaurPlus C21 CentaurPlus C27 ChannelPlus H11XL ChannelPlus H21XL ChannelPlus H21XL 425 Diadem/Tiara or ChannelPlus H21XL ChannelPlus H17XL ChannelPlus H27XL CentaurPlus C11 CentaurPlus C17 CentaurPlus C17 ChannelPlus H17XL CentaurPlus C11 CentaurPlus C21 CentaurPlus C21 CentaurPlus C27 CentaurPlus C17 CentaurPlus C27 CentaurPlus C11 CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C21 CentaurPlus C27 CentaurPlus C17 CentaurPlus C27 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C21 or ChannelPlus H21XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C27 or ChannelPlus H27XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C17 or ChannelPlus H17XL

50


GLOWORM HONEYWELL

HORSTMANN

MYSON

POTTERTON

SALUS CONTROLS

Common Time Base

Programmer

Mini-Programmer

Timeswitch

Replacement and re-wiring of backplate required*

1.5 Circuits

Two Circuit

Single Circuit

Two Channel

Single Channel

7 day

5/2 day

24 Hour

Model

Electronic

Manufacturer

Direct plug in replacement with simple wiring changes*

Electro-mechanical

Direct plug in replacement

Replace backplate but terminal connections remain the same

*Please see wiring comparison tables located in this guide

Recommended Replacement

Tempus 3 Tempus 4 Tempus 6 Tempus 7 Tempus 6-2 Tempus 7-2

CentaurPlus C21 CentaurPlus C27 CentaurPlus C21 CentaurPlus C27 CentaurPlus C27 CentaurPlus C27

Tempus 1-Mk2 Tempus 2-Mk2 Masterminder ST1000 ST1501 ST1507 ST6100A ST6100C

CentaurPlus C17 or ChannelPlus H17XL

ST6200A ST6300A ST6400C ST6450B ST699B Fully Pumped ST699B Gravity ST7000A ST7000B ST7100 ST799A ST9100A ST9100C ST9400A ST9400C ST9500C 423 Amethyst 10 423 Amethyst 7 423 Diamond 423 Emerald 423 Pearl Auto 424 Coral 424 Diamond 424 Emerald 424 Gem 424 Pearl Auto 425 Coronet 425 Diadem 425 Tiara 517 525 527 Centaur SC1 Centaur SC7 Centaur TC1 Centaur TC7 Microtimer One Microtimer Seven MEP1C MEP2C EP 2000 EP2001/EP2002 EP3000 EP3001/EP3002 EP4000 EP4001/EP4002 EP5001/EP5002 EP6000/EP6002 Mini Minder Mini Minder E Mini Minder ES EP100 EP101 EP200

CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C21 425 Diadem/Tiara or ChannelPlus H21XL ChannelPlus H21XL ChannelPlus H27XL CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C21 CentaurPlus C21 CentaurPlus C27 CentaurPlus C27 CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C27 or ChannelPlus H27XL ChannelPlus H27XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Coronet or ChannelPlus H11XL 425 Diadem or ChannelPlus H21XL 425 Tiara or ChannelPlus H21XL ChannelPlus H17XL (75mm clearance required to left of existing programmer) ChannelPlus H21XL (75mm clearance required to left of existing programmer) ChannelPlus H27XL (75mm clearance required to left of existing programmer) CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C21 CentaurPlus C27 CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C21 CentaurPlus C21 CentaurPlus C11 CentaurPlus C17 CentaurPlus C17 CentaurPlus C27

51


M5 M6 ‘SIEMENS/ RWB100 LANDIS & RWB102 STAEFA and RWB152 LANDIS & GYR RWB170 RWB2/RWB2E RWB200 RWB252 RWB270 RWB30/RWB30E RWB40 RWB50 RWB7 RWB9 RWB27 RWB29 RWB1001

SUNVIC

TIMEGUARD/ SMITHS

RWB1007 RWB2001 RWB2007 MP2 Select 107/107 XLS Select 207/207 XLS SP100 SP20 SP35 SP25/SP30 SP50 Centroller 100 Centroller 1000 Centroller 30/50

Centroller 60/90 Centroller 70 TRT034 TRT036 TOWERCHRON/ DP72 GRASSLIN DT71 QE1 QE2 QM1 QM2 T2001/T2001Q T2002/T2002Q T2003/T2003Q VENNER T10 T20/T30 Venotime Venetrol 80/80M/80P

Common Time Base

Programmer

Mini-Programmer

Timeswitch

1.5 Circuits

Replacement and re-wiring of backplate required*

Two Circuit

Single Circuit

Two Channel

Single Channel

7 day

5/2 day

24 Hour

Model

SANGAMO

Electronic

Manufacturer

Direct plug in replacement with simple wiring changes*

Electro-mechanical

Direct plug in replacement

Replace backplate but terminal connections remain the same

*Please see wiring comparison tables located in this guide

Recommended Replacement 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C11 CentaurPlus C21 (Mid Position System - Use Gravity Mode) CentaurPlus C17 CentaurPlus C17 CentaurPlus C21 CentaurPlus C21 CentaurPlus C27 CentaurPlus C27 CentaurPlus C11 CentaurPlus C21 CentaurPlus C11 CentaurPlus C17 CentaurPlus C27 CentaurPlus C17 CentaurPlus C27 CentaurPlus C11 CentaurPlus C17 CentaurPlus C21 CentaurPlus C27 CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C17 CentaurPlus C27 CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C11 or ChannelPlus H11XL CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C21 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C27 or ChannelPlus H27XL CentaurPlus C27 CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C17 or ChannelPlus H17XL CentaurPlus C27 425 Coronet 425 Tiara 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL 425 Coronet or CentaurPlus C11 or ChannelPlus H11XL 425 Diadem/Tiara or CentaurPlus C21 or ChannelPlus H21XL

52


Wiring comparison table - Timeswitches

MAINS E

N

L

SPARE COM

MAINS

OFF

ON

3

4

E

N

L

1 1 1 1 6 6 6 4 4 4 3 3 3 3 1 1 3 7 2 2 3 3 4 4 3 4 4 4 4 4 4 3 3 4 4 4 4 4 4 3 3 1 5 5 3 4,5

4 4 4 4 E E E

5 5 5 5 N N N N N N N N N N N,2 N N 2 N N N N N N N N N N N N N N N N N N N N N N N 4 N N N 1 2 N N N N N N N N

6 6 6 6 L L L L L L L L L L L L L 1 L L L L L L L L L L L L/1 L/1 L L L L L L L L L L 6 L L L 2 1,5 L L L L L L L L

E

Centaurplus C11 or C17

Manufacturer DANFOSS RANDALL

DRAYTON/ ACL/INVENSYS

HONEYWELL

HORSTMANN

MYSON POTTERTON

SALUS CONTROLS SANGAMO SUNVIC

TIMEGUARD/ SMITHS

Model

103 103E 103E5 103E7 911 917 971 TS15 TS75 TS715 LP111 LP711 LS111 LS711 Switchmaster 300 Switchmaster 980 SM1 TC Tempus 1 Tempus 2 Tempus 1-Mk2 Tempus 2-Mk2 ST6100A ST6100C ST7000B ST9100A ST9100C 423 Emerald 423 Pearl Auto 424 Emerald 424 Pearl Auto Centaur SC1 Centaur SC7 MEP1C EP4000 EP4001 EP4002 EP5000 EP5002 EP100 EP101 M6 Sunvic SP20 SP35 Select 107/107XLS Centroller 30

Centroller 50 TRT034 TOWERCHRON/ DT71 GRASSLIN QE1 QM1 T2001 T2001Q VENNER T10 Venotime

E

N

L

1

2

4 4 4 4 E E E

5 5 5 5 N N N N N N N N N N N,2 N N 2 N N N N N N N N N N N N N N N N N N N N N N N 4 N N N 1

6 6 6 6 L L L L L L L L L L L L L 1 L L L L L L L L L L L L,1 L,1 L L L L L L L L L L 6 L L L 2

2 2 2 2 2 2 2 3 3 3 4 4 4 4

4

3 3 3 3 5 5 5 1 1 1 1 1 1 1 4 4 1

4 4 4 4 3 3

1 1 1 1 1 1

3 3 5,6 5,6 5 5 4 4 1 A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D

1 1 3 3 3 3 1 1 3 5 5 5 5 5

2

4 3 3 3 1

2 N N N N N N N N

1,5 L L L L L L L L

E E E E E E E E E E E

E E E E E E E

E E

S S

1 1

3 3 3

2 2

N

L

SPARE

ON

COM

OFF

425 Coronet or ChannelPlus H11/H17

4 4 4 2 2 2 2 2 2 2

2 3 3 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 1 1 2 4 4 2 3,6 NC1 2 2 2

1 1

4 NO1 4 4 4 7 7 3 3

E E E E E E E E E E E

E E E E E E E

E E

1,2,3 2 2 2 2 2 2 2 3 3 3 4 4 4 4

4 4 4 4 4 3 3 3 3 5,6 5,6 5 5 4 4 1 A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D 2 S S

1

2

4

5

1 1 1 1 6 6 6 4 4 4 3 3 3 3 1 1 3 7 2 2 3 3 4 4 3 4 4 4 4 4 4 3 3 4 4 4 4 4 4 3 3 1 5 5 3 4,5 4 NO1 4 4 4 7 7 3 3

3 3 3 3 5 5 5 1 1 1 1 1 1 1 4 4 1 1 1 1 1 1 1 1 1 3 3 3 3 1 1 3 5 5 5 5 5 4 3 3 3 1

6

4 4 4 2 2 2 2 2 2 2

2 3 3 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 1 1 2 4 4 2 3,6 NC1

3 3 3

2 2 2

2

1 1

Timeswitches: Terminal 1 on the CentaurPlus and the Terminals 1, 2 & 3 on the ChannelPlus and 425 Coronet models detailed within the Timeswitch table are SPARE or Linking terminals. In the event that the number of spare terminals used on the timeswitch being replaced exceeds those detailed above then any connected wires should be removed and re-connected into a separate piece of terminal block. Wires from different spare terminals should not be joined together.

53


Wiring comparison table - Programmers

MAINS E

N

L

E

N

L

E E E 8 8

5 5 5 1,7 7

6 6 6 6 6

922 972 DRAYTON/ LS112 ACL/INVENSYS FP MP Switchmaster 320 Switchmaster 350 Switchmaster 400 Switchmaster 600 Switchmaster 805 Switchmaster 900 Switchmaster 9000 Switchmaster 9001

E E E E E E E E E E E E E

N N N 2 2 N,2 N,2 N N N N N N

Switchmaster 905 Switchmaster Sonata SM2 HONEYWELL ST699B - Fully Pumped ST699B - Gravity ST7000A ST7100 ST799A ST9400A ST9400C ST9500C HORSTMANN 423 Amethyst 10 423 Amethyst 7 423 Diamond 424 Coral 424 Diamond 424 Gem MYSON Microtimer One Microtimer Seven MEP2C POTTERTON EP2000 EP2001 EP2002 EP3000 EP3001 EP3002 EP6000 EP6002 SANGAMO M5 SUNVIC MP2 SP100 SP25 SP30 SP50 TIMEGUARD/ Centroller 100 SMITHS Centroller 60 Centroller 70 Centroller 90 TRT036 TOWERCHRON/ QM2 T2002 GRASSLIN T2002Q T2003 T2003Q VENNER Venetrol 80 Venetrol 80M Venetrol 80P Venner T20 Venner T30

E

HW OFF

CH OFF

HW ON

CH ON

SPARE

NONE

MAINS E

N

Centaurplus C21 or C27

Manufacturer Model DANFOSS RANDALL

102 102E 102E5/102E7 3020P/3060 4033

E E E E E E E E E E E E E

E E E E E E E E E E E E E E E E E E E E E E E E E E E

3

4

5

3

1 1 1 4 4

2 2 2 2 2

L L L 1 1 L L L L L L L L

1 1 2 8

4 4

4 4 4 4

2 2 2 2

3 3 3 6 6 3 3 3 3 3 3 3 3

6 6 4 10 10 1 1 1 1 1 1 1 1

N N N N N N N N N N N 2,3 2,3 N 2,3 N 2,3 N N N N N N N N N N N 4,5 N N N N N N 1 1 1 N N

L L L L L L L L L L L 1 1 L 1 L/1 1 L L L L L L L L L L L 3 L L L L L L 2 2 2 L L

4 3 1 7

2 6 2 4

2 7 7 1 1 1 4 4

4 4 2 2 2 6 6

N N N N N,1,3,4 N,3 N,1,3 N N

L L L L L L L L L

11

4

6 7 7 1 1 1 1 1 1 1 1 1 HW OFF 1 1 1 1

NC2 1

9 4 4 2 2 2 2 2 2 2 2 2

4

4

NC1 2

3 1 1 4 3 4 6 3 8 3 3 4 8 5 6 3 3 4 3 4 3 4 5 7 5 7 2 4 8 4 2 4 4 7 6 3 6 3 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 1 6 HW ON CH ON 2 5 2 5 2 5 2 5 3 2 5 4 5 4 5 4 NO2 NO1 4 3

HW ON HW ON HW OFF CH OFF HW ON HW OFF CH OFF HW ON 2 1 4 2 2 1 1 3 2

HW ON

COM

HW OFF

CH ON

COM

CH OFF

SPARE

425 Diadem/Tiara or ChannelPlus H21/H27

2

1

L

3,5

3 3,7,8

2 2,4 A,B,C A,B,C A,B,C

N

L

1

2

E E E 8 8

5 5 5 1,7 7

6 6 6 6 6

1 1 1 4 4

3 3 3

E E E E E E E E E E E E E

N N N 2 2 N,2 N,2 N N N N N N

L L L 1 1 L L L L L L L L

3 3 3 6 6 3 3 3 3 3 3 3 3

2 2

E

N N N N N N N N N N N 2,3 2,3 N 2,3 N 2,3 N N N N N N N N N N N 4,5 N N N N N N 1 1 1 N N

L L L L L L L L L L L 1 1 L 1 L/1 1 L L L L L L L L L L L 3 L L L L L L 2 2 2 L L

3 1 3 6 8 3 8 6 3 3 3 5 5 2 8 2 4 6 6 3 3 3 3 3 3 3 3 3 1 HW ON 2 2 2 2 3 5 5 5 NO2 3

N N N N N,1,3,4 N,3 N,1,3 N N

L L L L L L L L L

E E E E

5,6 5,6 5

E E E E E E E E E

A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D

E E E E E E E E E

S,S S,S,4 S,S,4 S,S 1,4 3,6 3,6 3,6

E E E E E E E E E

CH ON CH ON CH ON CH ON 5 5 A/S 4 4

E

A/S,4,5

E E E E E E E E E

3

4

5

6

5

2 2 2 2 2

1

3

5 5

4 4

1 1 2 8

4 4

4 4 4 4 4 3 1 7

6 6 4 10 10 1 1 1 1 1 1 1 1

1 4 4 8 3 6 3 2 4 6 7 5 8 7 3 1 4 1 4 1 4 4 7 4 7 1 4 4 4 5 6 7 8 7 3 8 7 3 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 6 HW OFF CH ON 1 5 1 5 1 5 1 5 2 4 4 4 NC2 NO1 3 1 HW ON CH ON HW ON CH ON HW ON COM HW OFF CH ON HW ON COM HW OFF CH ON 2 A/S 2 1 A,S 2 A/S 1 4 2 1 4

NONE

3,5

11

3 3,7,8

4

2 2,4

2 2 2 2

5 5 3 5

3 7 3 8 5 5 5 5 5 5 5 5 5 5

3 3 3 3

A,B,C A,B,C A,B,C

2 6 2 4

4 4 2 2 2 6 6 5,6 5,6 5 9 4 4 2 2 2 2 2 2 2 2 2

4

4

A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D

S,S S,S,4 S,S,4 S,S 1,4 3,6 3,6 3,6

NC1 2

COM CH OFF COM CH OFF 4

A,S,5 A/S,4,5 A/S,4,5

3

Programmers: The CentaurPlus and 425 Series models detailed within this programmer table do not have any SPARE or LINKING terminals. If spare terminals have been used on the programmer being replaced then any connected wires should be removed and re-connected into a separate piece of terminal block.

54


DRAYTON/ ACL/INVENSYS

HONEYWELL

MYSON

SALUS CONTROLS

SIEMENS/ LANDIS & STAEFA and LANDIS & GYR

SUNVIC

DIGISTAT+ DIGISTAT+ RF RTS1 RTS2 RTS3 RTS4 RTS5 RTS8 (Combi Stat) HTS3 DT90E DT92E DT200 T4360A T4360B T6360B Y6630D L641A MRT E MRT 1 MCT 1 FT 100 RT 100 RT 200 RT 300 ST 320 CT 100 RAA 10 RAA 20 RAA 20-GB RAA 20 LD-GB RAD1-F RDD10 RDD10.1 RDH10-GB RDH10-RF RAM1 TLX 2251 TLX 2259 TLX 2356 TLX 2358 TLX 2360 TLX 5101 TLX 7501 TLX 9201 TLX RFD SA 2452

TPI - Chrono Proportional

Tamperproof

Back-Lit Display

Contact Rating (Amps)

Changeover Contacts

Volt Free Contacts

Neutral Required

Wireless & Receiver

Battery Operation

24 Volt Operation

Mains Operation

Electronic (Digital Only)

Electronic (Dial & Digital Only)

Electronic (Dial Only)

Electro-Mechanical

RET 230 RET 230 F RET 230 P RET B RET B-RF RET 24 RET 24 VF RMT 230 RMT 230 VF RMT 24 ATC

Frost Stat

Model

DANFOSS RANDALL

Cylinder Stat

Manufacturer

Room Stat

Thermostat Compatibility Guide

Recommended Replacement

3 3 3 3 3 3 3 10 10 10 6 2 2 2 2 2 2 2 3 3 8 5 8 10 16 10 10 4

HRT4-B

8 15 15 8 3 3 3 10 16 6 10 6 6 10 5 5 5 8 15 1 6 6 6 6 10 2 10 6 5

HRT4-B

HFT4 HRT4-B HRT4-B HRT4-ZW HRT4-B HRT4-B HRT4-B (or HRT4-A without changeover switch) HRT4-B HRT4-B HCT2 HRT4-B HRT4-ZW HRT4-A HRT4-A HFT4 HRT4-B HRT4-B HRT4-A HCT2 HRT4-B HRT4-ZW HRT4-B HFT4 HRT4-A HRT4-B (or HRT4-A without changeover switch) HRT4-B HCT2 HRT4-A HCT2 HFT4 HRT4-B HRT4-A HRT4-B HRT4-B HCT2 HRT4-B (without Tamperproof cover) HRT4-B HRT4-B HRT4-B HFT4 (no changeover switch) HRT4-B HRT4-B HRT4-B HRT4-ZW HCT2 HRT4-B HRT4-A HRT4-B (or HRT4-A without changeover switch) HTT4 (no changeover switch) HFT4 HRT4-A HRT4-B HRT4-B HRT4-ZW HCT2

Please Note: All Horstmann Thermostats listed as the Recommended Replacement are only rated at 3 Amps. In the event that the installation requires a greater switch rating then they cannot be offered as a replacement.

55


Changeover Contacts

7 Day

5-2 Day

24 Hour

Wireless

Mains

Battery

Programmable Thermostat Compatibility Guide

Recommended Replacement

Manufacturer

Model

DANFOSS RANDALL

TP4000

C-Stat 11-B

TP4000 RF

C-Stat 11-ZW

HONEYWELL

DRAYTON / ACL / INVENSYS

SIEMENS

MYSON

SUNVIC

SALUS

TP5000 RF

C-Stat 17-ZW

TP7000

C-Stat 17-B

TP7000 M

C-Stat 17-M

TP7000 RF

C-Stat 17-ZW

CM701

C-Stat 11-B

CM707

C-Stat 17-B

CM901

C-Stat 11-B

CM907

C-Stat 17-B

CM921 +Receiver

C-Stat 11-ZW

CM927 +Receiver

C-Stat 17-ZW

CM 721+ Receiver

C-Stat 11-ZW

CM 727 +Receiver

C-Stat 17-ZW

Digistat +2

C-Stat 11-B

Digistat +3

C-Stat 17-B

Digistat +2 Mains

C-Stat 11-M

Digistat +3 Mains

C-Stat 17-M

Digistat +2 RF

C-Stat 11-ZW

Digistat +3 RF

C-Stat 17-ZW

REV 13

C-Stat 11-B

REV 12

C-Stat 11-B

REV 11

C-Stat 11-B

REV 10

C-Stat 11-B

REV 100

C-Stat 11-B

REV 17

C-Stat 17-B

REV 21

C-Stat 17-B

REV 22

C-Stat 17-B

REV 23

C-Stat 17-B

REV 23 RF

C-Stat 17-ZW

REV 200

C-Stat 17-B

REV 24

C-Stat 17-B

MPRT

C-Stat 11-B / C-Stat 17-B

MPRTRF

C-Stat 11-ZW / C-Stat 17-ZW

TLX 6501

C-Stat 11-B

TLX RFPv

C-Stat 11-ZW / C-Stat 17-ZW

RT500

C-Stat 17-B

RT 500 RF

C-Stat 17-ZW

56


Notes

57


@

South Bristol Business Park, Roman Farm Road, Bristol, BS4 1UP t: +44 117 978 8700 | f: +44 117 9788701 | e: sales@horstmann.co.uk | www.horstmann.co.uk Horstmann is a trading name of Secure Controls (UK) Ltd., a wholly owned subsidiary of Secure Holdings PTE Ltd. Registered office: Secure House, Moorside Road, Winnall Trading Estate, Winchester, Hampshire, SO23 7RX. Registered in England No. 457553 Š January 2013: Secure Controls (UK) Ltd: All rights reserved. The company reserves the right to alter product specifications without notice.

Part Number BGX501-834 Issue 2


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.