Download Print this page

Lux Products 605/2110 SERIES Installation And Operating Instructions

Programmable heat pump thermostat

Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS
605/2110 SERIES
PROGRAMMABLE HEAT PUMP THERMOSTAT
UP
MO
DAY
HEAT
PM
DOWN
MO
DAY
UP
HEAT
PM
DOWN
SET
SET
SATURDAY
SUNDAY
PROGRAM
PROGRAM
RESET
FAN
AUTO
SET
WEEKDAY
FILTER
HOLD
ON
PROGRAM
SET
RUN
DAY/TIME
NEXT
P a t e n t s P e n d i n g
SIMPLIFIED INSTRUCTIONS
TO SET TIME & DAY
• Press UP/DOWN to set time.
TEMPORARY TEMPERATURE OVERRIDE
• Rotate Dial to SET
•Press UP/DOWN to adjust set temperature.
DAY/TIME.
TO SET PROGRAMS
•To clear OVERRIDE press UP/DOWN until
• Press UP to change
• Rotate Dial to SET
original set temperature appears or wait for
Installs Easily
Set Day & Time
Fácil de Instalar
Programe el día y la hora
Complete, Easy To Read
Programming And Installation
Instructions Inside
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA
I M P O R T A N T !
Thank you for your confidence in our product. To obtain the best results from
your investment, please read these instructions and acquaint yourself with
READ
your purchase before installing your new thermostat. Then follow the installa-
INSTALLATION
tion procedures, one step at a time. This will save you time and minimize the
INSTRUCTIONS
chance of damaging the thermostat and the systems it controls.
These instructions may contain information beyond that required for your par-
FIRST
ticular installation. Please save for future reference.
FEATURES
The Active Program Period
The Unit can be
used with most
Programming
two stage heat
Dial
and one stage
cool heat pump
systems. It cannot be
MO
used with 120 volt
heating systems. Ask your
PM
dealer for other LUX ther-
mostats to control those
SET
SATURDAY
systems.
PROGRAM
SET
WEEKDAY
• The Unit is programma-
PROGRAMS
SET
ble. There are four pro-
DAY/TIME
gramming periods per day.
Each period can be pro-
PROGRAM
REVIEW
grammed separately.
• You can use the built-in
time/temperature pro-
grams, or alter them to
suit your schedule. The
Rotate the
dial to the
Unit provides separate
RUN
position
to close the
door.
programming for every
day of the week- for both
Program Review Button
heating and cooling. You
can override the
programmed temperatures for as little as one programming period or for an entire vacation.
• In cool weather, when the system switch is set to HEAT, the Unit will maintain cooler "set back"
room temperatures to save energy. It will then change to warmer "comfort" settings — all
automatically, at specified times during the day.
• In warm weather, when the system switch is set to COOL, the Unit will maintain warmer "set
back" room temperatures to save energy. It will then change to cooler "comfort" settings - all
automatically, at specified times during the day.
• A large liquid crystal display shows time, day of the week, and room and set temperatures.
It will remind you when the filter should be changed in your blower and track your system's
energy usage.
• Temperature swing adjustment lets you fine-tune your system for maximum comfort and
economy.
• A 4-minute minimum on/off time in COOL prevents your air conditioning system from being
damaged.
• Two "AA" batteries (not included) are used to retain your time and
temperature programs.
C
A
U
• Your thermostat is a precision instrument. Please handle it with care.
• Turn off electricity to the appliance before installing or servicing thermostat or any part
of the system. Do not turn electricity back on until work is completed.
• Do not short (jumper) across electric terminals at control on furnace or air conditioner
to test the system. This will damage the thermostat and void your warranty.
• All wiring must conform to local codes and ordinances.
• This thermostat is designed for use with 24 volt and millivolt systems. The thermostat
should be limited to a maximum of 1.0 amps; higher amperage may cause damage
to the thermostat. If you are in doubt, call your utility company.
Easy as
MO
UP
DAY
HEAT
PM
DOWN
SET
SET
SATURDAY
SUNDAY
RESET
HEAT
PROGRAM
PROGRAM
FAN
HEAT
AUTO
OFF
SET
OFF
WEEKDAY
FILTER
HOLD
ON
COOL
PROGRAM
COOL
SET
RUN
NEXT
DAY/TIME
1500
1500
P a t e n t s P e n d i n g
1–2–3
SIMPLIFIED INSTRUCTIONS
TO SET TIME & DAY
• Press UP/DOWN to set time.
TEMPORARY TEMPERATURE OVERRIDE
• Rotate Dial to SET
•Press UP/DOWN to adjust set temperature.
DAY/TIME.
TO SET PROGRAMS
•To clear OVERRIDE press UP/DOWN until
• Press UP to change
• Rotate Dial to SET
original set temperature appears or wait for
rr t d
WEEKDAY
the start tf the next period
Choose Heat or Cool
Escoja Calentar O Enfríar
Instrucciones Completas y Fáciles
de Leer Para Su Programación
E Instalación Incluídas Dentro
The Set
Liquid Crystal
Temperature
Display
UP
DAY
HEAT
DOWN
SET
SUNDAY
RESET
FAN
PROGRAM
EMER
AUTO
HEAT
AIR
HOLD
ON
FILTER
OFF
COOL
RUN
NEXT
Patent No. 5,673,850
SIMPLIFIED INSTRUCTIONS
• Press UP/DOWN to set time.
TEMPORARY TEMPERA TURE OVERRIDE
TO SET TIME & DAY
• Rotate Dial to SET
•Press UP/DOWN to adjust set temperatur e .
DAY/TIME.
TO SET PROGRAMS
•To clear OVERRIDE press UP/DOWN until
• Press UP to change
• Rotate Dial to SET
original set temperature appears or wait for
current day .
WEEKDAY,
the start tf the next period.
• Press NEXT .
SATURDAY or
SUNDAY PROGRAM.
TEMPERATURE HOLD
• Press UP/DOWN to adjust
• Press HOLD. Adjust temperatur e as
start time.
desired with UP/DOWN.
• Press NEXT .
•To clear, press HOLD again.
• Press UP/DOWN to adjust
temperature.
Need Help? Call 1-800-421-1130
• Press NEXT .
• Repeat as needed or rotate
dial to RUN to stop Programming.
T
I
O
INSTALLATION
Please read all instructions carefully
before beginning installation.
TOOLS REQUIRED
#1 Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
THERMOSTAT LOCATION
On replacement installations, mount the
new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new
installations, follow the guidelines listed below.
1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is
used often.
2. Do not install it where there are unusual heating conditions, such as: in direct
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near hot water pipes in a wall;
near a stove on the other side of a wall.
3. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in
a draft from a stairwell, door, or window.
4. Do not locate in a damp area. This can lead to corrosion that will shorten
43314
Rev C
thermostat life.
5. Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an open
door.
6. Do not install the unit until all construction work and painting has been completed.
7. This thermostat does not require leveling.
REMOVING THE OLD THERMOSTAT
Switch electricity to the furnace and air conditioner OFF; then pro-
ceed with the following steps.
1. Remove cover from old thermostat. Most are snap-on types
and simply pull off. Some have locking screws on the side.
These must be loosened.
2. Note the letters printed near the terminals. Attach labels
(enclosed) to each wire for identification. Remove and label
wires one at a time. Make sure the wires do not fall back inside
the wall.
3. Loosen all screws on the old thermostat and remove it from the
wall.
MOUNTING THE UNIT ON THE WALL
1. Strip insulation 3/8 in. (9.5mm) from wire ends and clean off any corrosion.
2. Fill wall opening with non-combustible insulation to prevent
Thermostat
drafts from affecting the thermostat.
Body
3. Press up on the button on bottom of thermostat and swing the
body away from the base and up to remove the body from the
System
Switch
base.
Fan
Switch
Leave the cover closed while the body is being removed from the base.
Easy to
follow
instructions
TERMINALS
Thermostat
Cover
SCREW
ANCHORS
Attaching Wires
4. Hold the base against the wall, with the wires coming through wherever
it is convenient for wiring. Route the wires to below the terminal block.
Position the base for best appearance (to hide any marks from an old
thermostat). Attach the base to the wall with the two screws provided.
WARNING: Use Energizer® or
N
DURACELL® Alkaline Batteries ONLY
for all Lux thermostats requiring batteries.
C A U T I O N
To avoid electrical shock and
to prevent damage to the
furnace, air conditioner, and
thermostat, disconnect the power
supply before beginning work. This
can be done at the fuse box, at the
circuit breaker, or at the appliance.
C
A
U
T
I
Be careful not to drop the body or disturb electronic parts.
W3
E G Y R O W2 B
L
BASE
OFF
C A U T I O N
Read instructions carefully
before removing any
wiring from existing
thermostat. Wires must be
labeled before they are
removed. When removing
wires from their terminals,
ignore the color of the
wires since these may not
comply with the standard.
O
N
N O T E
If you are mounting the base to
a soft material like plasterboard
or if you are using the old
mounting holes, the screws
may not hold. Drill a 3/16-in.
(4.8mm) hole at each screw
location, and insert the plastic
anchors provided. Then mount
the base as described below.

Advertisement

loading

Summary of Contents for Lux Products 605/2110 SERIES

  • Page 1 E Instalación Incluídas Dentro 4. Do not locate in a damp area. This can lead to corrosion that will shorten 43314 LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA Rev C thermostat life. I M P O R T A N T ! 5.
  • Page 2 INSTALLING BATTERIES The Unit requires batteries to operate your furnace and Open Close Do not allow wires to touch each other or parts on thermostat. Wires must be 24 Hr 12 Hr retain its programming in memory. Replace the batteries trapped between black spacer and brass terminal.
  • Page 3 PROGRAMMING THE UNIT ADVANCED FEATURES You can change any preset times and/or temperatures to suit your schedules for the weekday, Saturday and Sunday programs. Each HEAT and COOL may period (Morning, Day, Evening, and Night) is programmed for HEAT have different temperatures. FILTER USAGE MONITOR and for COOL.