1 / 27

PCS 7/505 OS V7.0 for use with 505 Controllers

PCS 7/505 OS V7.0 for use with 505 Controllers. SE&A AMD PAS. APT/ TiSoft/ SoftShop. PCS OSx / PCS / TiStar Stations. …. Engineering Tool. HMI. Network. Ethernet SINEC H1 TF/TiWay. Controller. Field Termination. 1. 2. 3. n. I/O. Field wiring. Field devices.

shelly
Download Presentation

PCS 7/505 OS V7.0 for use with 505 Controllers

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PCS 7/505 OS V7.0for use with 505 Controllers SE&A AMD PAS

  2. APT/ TiSoft/ SoftShop PCS OSx / PCS / TiStar Stations … Engineering Tool HMI Network Ethernet SINEC H1 TF/TiWay Controller Field Termination 1 2 3 n I/O Field wiring Field devices 505 System Architecture

  3. SIMATIC 505, OSx, and TiStar Product Status SIMATIC 505 • Phase-Out Stage • Spares can be purchased • Guaranteed support until 1-Feb-2015 TISTAR / PCS / OSx (all versions) • Discontinued Stage • Product can no longer be purchased • Guaranteed support no longer available

  4. Path Forward  PCS 7 • OSx  PCS 7 OS • SIMATIC 505  PCS 7 AS • Path to PCS 7 can be phased • Enables full lifecycle utilization of the 505 solution components • Products to support transition to PCS 7 are available • 505-CP1434TF - Allows reuse of 505 Controllers in a TISTAR system (TIWAY comm  TF- H1 Ethernet comm) • RBC-505-6870 – Allows reuse of 505 I/O • Graphics conversion service

  5. PCS 7 ES PCS 7 OS Clients APT Engineering PCS 7 / 505 Servers Ethernet TF RBC TI505 Example Migration Strategy – HMI Change-out • Change-out • HMI • SW Applications • Retain • 505 Controller Engineering Tool • 505 Controllers • 505 I/O Modules • Field Wiring

  6. PCS 7 OS Clients PCS 7 ES APT Engineering PCS 7 OS Servers IE TF Ethernet Ethernet 417 417H 555 RBC PROFIBUS SIMATIC PCS 7 TI505 Example Migration Strategy – Process Expansion PCS 7/505 OS Servers • Change-out • HMI • SW Applications • Retain • 505 Controller Engineering Tool • 505 Controllers • 505 I/O Modules • Field Wiring • Add • Pure PCS 7 components

  7. PCS 7 OS Clients PCS 7 ES PCS 7 OS Servers Industrial Ethernet AS controllers AS controller PROFIBUS I/O PROFIBUS RBC DP DP/PA-Link PROFIBUS F-SM Example Migration Strategy – Change-out HMI / Controllers • Change-out • HMI • SW Applications • 505 Controller • 505 Controller Engineering Tool • Retain • 505 I/O Modules • Wiring

  8. C505 DBA Toolset PCS 7 Products PCS 7 OS Servers PCS 7 ES (SIMATIC Manager) Graphics Designer DBA Control Center PCS 7 OS Clients Runtime Extension Framework Native 505 Channel APT / TiSoft / SoftShop Engineering Tool 505 Controllers TiStar / PCS / PCS OSx PCS 7/505 OS Migration Product Component

  9. PCS 7 OS Client PCS 7 Engineering APT Engineering Ethernet Install.Tag PCS 7 / 505 OS Server SIMATIC 505 Controller 1 2 3 n Field Termination Field wiring Field devices Database Automation (DBA) • DBA reads the 505 export file (install.tag) • Controller Objects (grouping of Tags) • Alarm config data (messages, class, type, and priorities) • Alarm triggers (High, Low, and Deviation) • DBA provides tools to: • Organize Controller objects in a hierarchical based on plant areas to facilitate navigation, alarm management, graphics content, and security implementation • Compile, Download to PCS 7 OS

  10. OSx 4.1.2 or OSx 4.1.2A APT Pre OSx 4.1.2 or OSx 4.1.2A OSx 4.1.2 or OSx 4.1.2A Configuration Tool TISOFT APT Export Pre OSx 4.1.2 or OSx 4.1.2A OSx Service OSx Service OSx Service OSx Export OSx Export OSx Export Manual Manual Manual OSx 4.1.2 or OSx 4.1.2A SoftShop Pre OSx 4.1.2 or OSx 4.1.2A Sources of Install.Tag file

  11. Database Automation (DBA)User Interface Layout C505 Plant Hierarchy (8 Lvls) (S88 compliant) Controller objects assigned to the Technological Hierarchy Flat list of controller objects (PID, Motor, etc.) List of Legacy Controller’s

  12. Database Automation (DBA) Supported SIMATIC 505 Controller Objects • MTR1 – Non-reversible Motor • MTR2 – Two Speed Motor • CALC – Calc Variable • IVAR – Integer Variable • TMR – Timer • CTR – Counter • LOOP – Loop • TEXT – Three text strings • UNIT – Unit • AREA – Area • AI – Analog input • AO – Analog Output • DI – Digital Input (1 bit/multiple bits) • DI10 – 10 bit Discrete Input • DO – Discrete Output • DO10 – 10 bit Discrete Output • VLV1 – Single Feedback Valve • VLV2 – Dual Feedback Valve • RMTR – Reversible Motor Note: Except for UNIT and AREA Block Types, all other Block Types includes a Faceplate and a Symbol

  13. Out-Of-The-Box Alarm Handling Capabilities Runtime Extension Framework– Alarm Handling • Alarm Persistence • Alarm Synchronization (Redundant Servers) • Alarm Detection, Ack, Disable Integrated Alarm Handling Subsystem V6.1

  14. PCS 7 OS Client PCS 7 Engineering APT Engineering Ethernet PCS 7 / 505 OS Server SIMATIC 505 Controller 88.8 88.8 on on 1 2 3 n Field Termination Field wiring Field devices 505 Channel Interface Server - Receive Device Status and Process Values

  15. PCS 7 OS Client PCS 7 Engineering APT Engineering Ethernet PCS 7 / 505 OS Server SIMATIC 505 Controller 88.8 88.8 on on 1 2 3 n Field Termination Field wiring Field devices Native 505 Channel Interface Server Send Device Commands and Process Values

  16. Pre-built PCS 7 Symbol Library for 505 Controller Objects

  17. Pre-built PCS 7 Faceplate Library for 505 Controller Objects Control Panel Alarm Settings Alarm List Tuning Panel Online Trend PID Faceplate

  18. Graphics Conversion Service (SHO R&D)

  19. Data Export Service (SHO R&D) • Action Requests • Recipes • Cross reference – tags / graphics

  20. Import Any Converted Graphics Create Hardware Structure Import 505 data into DBA Project Add Action Requests Structure tags in Plant View Create PCS 7 Project Compile / Download to OS Servers Start PCS 7 OS Basic Project Workflow V6.1

  21. Supported Product Architectures PCS 7 / 505 OS Single Station PCS 7 / 505 OS Engineering Pack APT Engineering Node TF Ethernet Single Station Architecture

  22. Supported Product Architectures PCS 7 / 505 OS Engineering Pack PCS 7 OS Software Client V6.1 PCS 7 / 505 OS Servers (Non Redundant) or PCS 7 / 505 OS Redundant Server Pack APT Engineering Node TF Ethernet Client – Server Architecture

  23. Supported Solution Architectures PCS 7 / 505 OS Engineering Pack Plus PCS 7 Engineering Software for AS PCS 7 OS Software Client V6.1 APT Engineering PCS 7 OS Server Software or PCS 7 Server Redundancy TF Ethernet Ethernet PCS 7 / 505 OS Servers (Non Redundant) or PCS 7 / 505 OS Redundant Server Pack 417 417H PROFIBUS TI505 Expansion Architecture SIMATIC PCS 7

  24. Supported Solution Architectures PCS 7 / 505 OS Engineering Pack Plus PCS 7 Engineering Software for AS PCS 7 OS Software Client PCS 7 / 505 OS Servers (Non Redundant) or PCS 7 / 505 OS Redundant Server Pack APT Engineering Ethernet TF Ethernet 417 SIMATIC PCS 7 TI505 Dual Leg PCS 7 / 505 OS Server Architecture

  25. PCS 7/505 OS V7.0 – What’s New • Re-validation (Support for PCS 7 V7.0 SP2) • Support for running on WinXP, Svr2003 • Support Web Read/Write to faceplates/symbols • Modified Runtime Framework to support Web Solutions • Configure short/long term tag archiving from DBA • Tags to archive • Tag archive rate

  26. Order InformationPCS 7/505 OS Software Packages

  27. Order InformationPCS 7/505 OS Upgrade Packages * Order one package for each 505 OS Engineering Station. The engineering station upgrade package provides two license disks. One disk upgrades Runtime, while retaining the same number of POs that your system had pre-upgrade. The other disk upgrades your engineering station to Unlimited POs but with only 2 hour runtime capability. ** Order one package for each 505 OS Server or Single Station *** Order one package for each PCS 7 Client Station

More Related